| AC
input: |
TPS50,
100, 150: 85 - 132/170 - 264V AC link change 47 -440Hz |
| Inrush
Current: |
TPS
50 - TPS150 40A max. |
| Hold
Up Time: |
TPS5O
lOms min TPS100 & 150 15ms min I/p 85 VAC Full Load |
| DC
Output: |
See
table |
| Minimum
Load: |
No
minimum load required |
| LED
Output Indicator: |
Indicated
output on front panel, mains failure on front panel |
| Line
Regulation: |
0.4%
max over specified input range |
| Load
Regulation: |
0.8%
max for 100% load change |
| Output
Ripple & Noise: |
4OmV
p-p typical (15OmV max) |
| Short
Circuit and Overload Protection: |
Operates
>105% of rating and recovers automatically |
| Overvoltage
Protection: |
Operates
at 115-140% of rating |
| Efficiency: |
80%
typical |
| Operating
Temperature: |
0
to + 500C (For extended temperature range see derating
curves). All models will operate at -200C with reduced
ripple and noise specification. Contact TASCOM International
Ltd. |
| Storage
Temperature: |
-
20 to + 750C |
| Temperature
Coefficient: |
0.02%/0C |
| Relative
Humidity: |
20
to 90% RH Non-condensing |
| Isolation: |
Input
- Output 3,75OVAC 1 ml 500VDC, 50 Mohm |
| EMI/RFI: |
Complies